Post-Test Answers & Explanations
Q1. Answer: B — Kidney Remember
The kidneys are the primary organs of the urinary system. Each kidney filters blood and produces urine. The liver, pancreas, and spleen belong to the digestive and lymphatic systems.
Q2. Answer: B — Two Remember
A normal healthy adult has two kidneys, located retroperitoneally on either side of the vertebral column, below the diaphragm. A person can survive with one kidney, but the standard anatomical complement is two.
Q3. Answer: B — Ureter Remember
The ureters are paired muscular tubes that transport urine from the renal pelvis of each kidney to the urinary bladder by peristaltic contractions. The urethra, in contrast, drains the bladder.
Q4. Answer: B — Nephron Remember
The nephron is the structural and functional unit of the kidney. Each kidney contains about one million nephrons, each consisting of a glomerulus, Bowman's capsule, and a renal tubule. The glomerulus is only one part of the nephron, so option D is incomplete.
Q5. Answer: C — Production of bile for fat digestion Remember
Bile is produced by the liver, not the urinary system. The urinary system removes nitrogenous wastes, regulates electrolytes and pH, helps control blood pressure (renin), and stimulates red blood cell production (erythropoietin).
Q6. Answer: B — Cortex Remember
The kidney has an outer cortex and an inner medulla. The cortex contains the renal corpuscles (glomeruli and Bowman's capsules) and the convoluted tubules, while the medulla contains the loops of Henle and collecting ducts.
Q7. Answer: B — Renal artery Remember
The renal artery branches from the abdominal aorta and delivers oxygenated blood into the kidney for filtration. The renal vein carries filtered blood away. The afferent arteriole is a smaller branch inside the kidney that feeds each glomerulus, but the question asks for the vessel entering the kidney as a whole.
Q8. Answer: A — Glomerulus Remember
Filtration begins in the glomerulus, a capillary tuft enclosed by Bowman's capsule. High pressure in the glomerular capillaries forces plasma (water and small solutes) into Bowman's capsule, forming the glomerular filtrate.
Q9. Answer: B — Urethra Remember
Urine flows from the kidneys → ureters → urinary bladder (storage) → urethra → out of the body during urination (micturition). The urethra is the final passageway.
Q10. Answer: A — Urea Remember
Urea, formed in the liver from ammonia breakdown of proteins, is the principal nitrogenous waste excreted in urine. Other wastes include creatinine and uric acid. Glucose and oxygen are not wastes.
Q11. Answer: B — About 83 mL/hr Apply
Calculation: 2 litres/day = 2000 mL/day ÷ 24 hours = 83.3 mL/hr. Normal daily urine output is roughly 0.8–2.0 litres; a sustained output below ~400 mL/day (oliguria) or above ~2.5 L/day (polyuria) is clinically significant — a fact relevant when designing urine-output monitoring devices.
Q12. Answer: C — Reabsorption Understand
Reabsorption is the movement of useful substances (glucose, amino acids, ions, ~99% of water) from the renal tubule filtrate back into the peritubular capillaries. Filtration occurs in the glomerulus; secretion moves substances from blood into the tubule (e.g., H⁺, K⁺, drugs); excretion is the elimination of urine.
Q13. Answer: B — The kidneys can no longer adequately filter waste products and excess fluid from the blood Understand
In kidney (renal) failure, the nephrons lose their filtering capacity, so urea, creatinine, excess fluid, and electrolytes accumulate in the blood (uraemia). Dialysis artificially performs the filtration, or a transplanted kidney restores the function. The bladder and lungs are not responsible for blood filtration.
Q14. Answer: A — Daily urine output and body weight Apply
Fluid overload in dialysis patients is detected by tracking daily urine output (oliguria signals poor renal function) and daily body weight (rapid weight gain indicates fluid retention). These are the standard quantities a biomedical monitoring device for dialysis patients would measure, typically using load cells and flow sensors.
Q15. Answer: A — The ureter carries urine from kidney to bladder; the urethra carries urine from bladder to outside the body Understand
The path of urine is a one-way system: kidney → ureter → bladder → urethra. Confusing the two is a common student error. Also, the male urethra is longer (~18–20 cm) and shared with the reproductive system, whereas the female urethra is shorter (~4 cm), which is why females are more prone to urinary tract infections.
Q16. Answer: B — Glucose is reabsorbed from the filtrate back into the blood by the renal tubules Understand
Glucose is freely filtered at the glomerulus but is normally 100% reabsorbed in the proximal convoluted tubule via carrier-mediated transport. Glucose appears in urine (glucosuria) only when blood glucose exceeds the transport maximum (~180 mg/dL), as in diabetes mellitus — a principle exploited in urine glucose test strips used in clinical diagnostics.
Q17. Answer: B — 1.0–1.25 L/min Apply
Calculation: 20–25% of 5 L/min = 0.20 × 5 = 1.0 L/min to 0.25 × 5 = 1.25 L/min. This high renal blood flow (about 1.1 L/min total, ~22% of cardiac output) ensures efficient waste clearance, illustrating why the kidneys are among the most perfused organs — important context when specifying blood-flow sensors for renal devices.
Q18. Answer: B — Increase water reabsorption, producing a smaller volume of more concentrated urine Understand
ADH (also called vasopressin), released from the posterior pituitary, makes the collecting ducts more permeable to water, so water is reabsorbed into the blood and urine becomes concentrated. It is secreted when the body is dehydrated. Diuretics and alcohol inhibit ADH, causing dilute, high-volume urine.
Q19. Answer: A — Blood flow rate (mL/min) compatible with the patient's circulation Apply
The blood pump in a haemodialysis machine must deliver a precise flow rate (typically 200–500 mL/min for adults) to ensure adequate clearance of toxins across the dialyser membrane without damaging blood cells or stressing the cardiovascular system. Flow rate, pressure monitoring, and air-bubble detection are core engineering design parameters for patient safety.
Q20. Answer: A — An elevated level of urea and creatinine in the blood Apply
Urea and creatinine are normally filtered and excreted by the kidneys. When filtration fails, they accumulate in the blood — elevated blood urea nitrogen (BUN) and serum creatinine are the standard clinical markers of reduced glomerular filtration rate (GFR). This is why renal function panels are essential inputs for dialysis scheduling algorithms and device design.